27Installation
Motor connections (all FHP-series controls)
Single-phase operation
For single-phase operation, connect the motor as shown in
Figure 15 (page 28). Ensure that the prewired capacitor
and its associated motor coil are connected to terminals U
and V as shown. This connection may be internal if using a
2-wire motor. If the motor has three leads, you must make
this connection yourself.
To reverse a single phase split capacitor motor, connect the
motor as shown in Figure 16 (page 29). The motor starter
cap must be removed from the circuit.
Three-phase operation
Connect a three-phase motor to terminals U, V and W as
shown in Figure 17 (page 30).