Vue de la page 35
30
Figure 17. RUN/JOG Switch Connection to Speed Adjust
Potentiometer
RUN/JOG switch
Using a RUN/JOG switch is recommended in applications where
quick stopping is not needed and frequent jogging is required. Use
a single pole, two position switch for the RUN/JOG switch, and a
normally closed, momentary operated pushbutton for the JOG
pushbutton (see Figure 17). When the RUN/JOG switch is set to
JOG, the motor decelerates to minimum speed. Press the JOG
pushbutton to jog the motor. Return the RUN/JOG switch to RUN
for normal operation.
S3
S2
S
1
10
K
O
H
M
S
PEED P
OT
JOG
RUN
JOG
P
US
HB
U
TT
ON
C
W
Application Notes