16
Motor connections
Motor connections are made to TB502
Single-phase operation
For single-phase operation, connect the motor as shown
below in Figure 7. Ensure that the prewired capacitor and
its associated motor coil are connected to terminals U and
V as shown. This connection may be internal if using a 2-
wire motor. If the motor has three leads, you must make
this connection yourself.
To reverse a single phase permanent split capacitor motor,
connect the motor as shown in Figure 8 (page 17). The
motor cap must be removed from the circuit.
Figure 7. Single Phase Operation (pre-wired cap)
DO NOT use a direction
switch with this setup
Vue de la page 24